Example Calculation
<table width="50% border="1"><tr><th>Line</th> <th>Item</th> <th>Amount</th> <th>Calculation</th> <th>Comments</th></tr>
<tr><td>A</td><td> Total Daily Load AC (DC AH)*</td><td> 200</td><td> &nbsp; </td><td> Normalize to 12 or 24 V(AC watts/DC voltage)</td></tr>
<tr><td>B</td><td> Total Daily Load DC AH</td><td> 50</td><td> &nbsp; </td><td> Normalize to 12 or 24 V</td></tr>
<tr><td>C</td><td> Total Daily Load AH</td><td> 250</td><td> = A + B</td><td> </td></tr>
<tr><td>Q</td><td> Required Charging Capacity AH</td><td> 418</td><td> = M + N + O + P</td><td> </td></tr>
<tr><td>R</td><td> Time to Charge Hours</td><td> 0.7</td><td> = E / M</td><td> </td></tr></table>
 
* Use AC Watts/DC Voltage
== Capacity of House Bank Required ==